> The Air Safety Product Range > Product Information  
 
Anaesthesia
Pleated Filters
Electrostatic
Machine End
Anaesthetic Face Masks
Catheter Mounts
Intensive Therapy
HMEF Electrostatic
HMEF Pleated
Ventilator Protection
Neonatal
Tracheostomy
Tracheal HME
Respiratory
Spirometry

Filters for CPAP/BIPAP Protection

Entonox Filter
CPAP/BIPAP
Suction Filters
Laparoscopic Surgery
Insufflation
Smoke Filtration
Suction Irrigation
Specialised


Intensive Therapy
HMEF Electrostatic  
Slimline HMEF  
9041/01
    Long Term Ventilation
  99.999% Bacterial/Viral Efficiency
  Electrostatic media
  Resistance to Flow 116 Pa @ 30 L.min-1
   33 g.m L-3 Moisture Output @ VT 500ml
  Deadspace 47ml
  Weight 32g  
  22M/15F - 15M/22F ISO Connectors  

Slimline Paediatric HMEF  
9065/01
    Short Term Anaesthesia
  99.999% Bacterial/Viral Efficiency
  Electrostatic media + HME
  Resistance to Flow 70 Pa @ 15 L.min-1
   31 g.m L-3 Moisture Output @ VT 250ml
  Deadspace 29ml
  Weight 18g  
  22M/15F - 15M Connectors  

HMEF Pleated  
Multipleat HEPA/HME  
8666/200
    99.9999% Bacterial/Viral Efficiency
  Pleated hydrophobic media
  Resistance to Flow 117 Pa @ 30 L.min-1
  31 g.m L-3 Moisture Output @ VT 500ml
   Deadspace 121ml
  Weight 58g
  22M/15F - 15M/22F ISO Connectors  
  Luer sampling port with high visibility cap'n'strap for improved patient safety  
 

 

All ASL pleated products are individually tested for efficiency according to BS EN 13328-1



Ventilator Protection - Pleated  
Multipleat HEPA/HME  
3000/03
    Lipped Connector
  99.99999+% Bacterial/Viral Efficiency
  Pressure Drop <2.0 cm H20 @ 100 L/min
  22mm ISO Connector
   Individually tested under BS EN 13328-1
  Weight 58g


Ventilator Protection - Pleated  
Multi-Purpose HEPA Filter  
3000/04
    Tapered Connector
  99.99999+% Bacterial/Viral Efficiency
  Pressure Drop <2.0 cm H20 @ 100 L/min
  22mm ISO Connector
   Individually tested under BS EN 13328-1
   

For electrostatic ventilator protection, see Anaesthesia Machine End Products

Neonatal HMEF  
9080/100
  99.999% Bacterial/Viral Efficiency
  Electrostatic media
  Resistace to Flow 163 Pa @ 15 L.min-1
  31 g.m-3 Moisture Output @ VT 50ml
   Deadspace 11ml
  Weight 9g
  22M/15F - 15M/22F ISO Connectors  
  Luer sampling port with high visibility cap'n'strap for improved patient safety  
  For use with patients 3-10kg  


Neonatal HME  
9085/01
    Suitable for Tracheostomy
  Resistance to Flow 232 Pa @ 15 L.min-1
  32.8 mg L-1 Moisture Output @ VT 25 ml
  Deadspace 2ml
   15M-15F - 15M Connectors
   
     

For further information and to request a sample, contact us.